Operation
975-0125-02-01 221
If you choose Yes, the equalization process is cancelled and you are returned to
the MS2000 home menu.
0R
If you choose No and continue with equalization, the equalization home screen, as
shown in Figure 2-14, appears.
5. When equalization is finished, check the battery electrolyte level. Top up as
necessary with distilled water only and recheck the specific gravity as
specified by the battery manufacturer.
Time Remaining Indicates the time left for equalization. Equalization
runs for 60 minutes; time is counted down in 1
minutes increments until the Time Remaining
displays 0 min. (During a precharge, the Time
Remaining displays n/a”— not applicable.)
Battery Voltage Displays a range of 13.2 V to 18.0 with increments of
0.1V.
Menu Pressing Menu returns you to Select Device screen.
Cancel Pressing Cancel will display a confirmation screen, as
shown in Figure 2-15, asking you to confirm that you
want to cancel equalization.
Figure 2-15
Equalize Cancellation Warning
Table 2-2
Equalization Home Screen Content
Equalization Home
Screen content Explanation of items displayed