Software Addendum
Software Enhancement
This version of the Link 10 includes special software.
F18 - SMALL BATTERY SENSING
DEFAULT: OFF Range: OFF, ON
When this function is OFF, the meter operates as described elsewhere
in this manual. When this function is ON, the amp-hour capacity range
allows capacities as low as 2 amp-hours to be declared. When ON,
capacity may be set from 2–200 amp hours, and small capacity
increments are allowed as follows:
From 2–40 amp hours, 1 amp-hour capacity increments are permitted.
Above 40 (to 198 amp hours), 2 amp-hour capacity increments are
permitted.