System Status Displays
975-0210-01-01 33
The Gen Quiet Fault error is automatically reset at the end of
the quiet time period if no other action is taken.
Figure 4-5
Gen Quiet Fault Error Message
Note: If the generator is manually started from the RC/GS, the
generator will not shut down automatically. “Man Stop Only”
(Figure 4-6) is displayed. Shut down the generator manually. See
“Generator Start/Stop (RC/GS Only)” on page 44.
Note: The Gen Quiet Fault error is not actually a system error or
fault but rather an alert that the generator has stopped because of
quiet time and an auto-start condition still exists.
Figure 4-6
Manual Stop Only Message
Inverter
Charge
Batt. Full
Error
822-4A-001
Genset Status:
Gen Quiet Fault
!
Red Error LED lights and error message
appears in the screen
Buzzer sounds
Genset Status:
MAN STOP ONLY
RC-GS_manual.book Page 33 Thursday, May 26, 2005 4:58 PM