Xantrex XPD 18-30 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Fahrwerkskomponenten Xantrex XPD 18-30 herunter. Xantrex XPD 18-30 User's Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - Power Supply

Operating ManualXPD 500 Watt SeriesProgrammable DC Power SupplyXPD 7.5-67XPD 18-30XPD 33-16XPD 60-9XPD 120-4.5

Seite 2

About This Manualviii Operating Manual for XPD Series Power SupplyPower Supply Safety MarkingsAlternating Current Off (Supply)Earth (Ground) Terminal

Seite 3 - XPD Series

Release A ixContentsAbout This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viiSection

Seite 4 - Warranty

x Operating Manual for XPD Series Power SupplySection 3.LocalOperationIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 5 - Release A iii

Release A 11Section 1. Features and SpecificationsDescriptionThe XPD Series of DC power supplies provides stable, variable output voltage and current

Seite 6 - Disclaimer Product

Section 1. Features and SpecificationsFront Panel Controls12 Operating Manual for XPD Series Power Supply• This unit may be equipped with an optional

Seite 7 - Canada V5A 4B5

Section 1. Features and SpecificationsRear Panel ConnectorsRelease A 13Rear Panel ConnectorsFigure 1.2 500 Watt Power Supply Rear Panel (7.5 V and 18

Seite 8

Section 1. Features and SpecificationsRear Panel Connectors14 Operating Manual for XPD Series Power SupplyOutputConnectorsLow Voltage Models Equipped

Seite 9 - About This Manual

Section 1. Features and SpecificationsRear Panel ConnectorsRelease A 15Rear PanelJ210ConnectorThe J210 Analog Interface connector is a 15-pin female D

Seite 10 - Power Supply Safety Markings

Section 1. Features and SpecificationsRear Panel Connectors16 Operating Manual for XPD Series Power SupplyTable 1.2 Rear Panel J210 Connector Pins an

Seite 11 - Contents

Section 1. Features and SpecificationsRear Panel ConnectorsRelease A 17Making J210ConnectionsWiringFor most connectors and jumpers, use any suitable w

Seite 13 - Release A 11

Section 1. Features and SpecificationsElectrical Specifications18 Operating Manual for XPD Series Power SupplyElectrical SpecificationsThese specific

Seite 14 - Front Panel Controls

Section 1. Features and SpecificationsAdditional SpecificationsRelease A 19Additional SpecificationsInput Conditions1. Front output current limited to

Seite 15 - Rear Panel Connectors

Section 1. Features and SpecificationsAdditional Characteristics20 Operating Manual for XPD Series Power SupplyAdditional CharacteristicsRemote Progr

Seite 16 - (Low Voltage Models)

Section 1. Features and SpecificationsEnvironmental SpecificationsRelease A 21Environmental SpecificationsMechanical SpecificationsOperating Temperatu

Seite 17

Section 1. Features and SpecificationsMechanical Specifications22 Operating Manual for XPD Series Power SupplyMounting Optional 19 in. (483 mm) rack

Seite 18

Release A 23Section 2. InstallationIntroductionThis section provides recommendations and procedures for inspecting, installing, and testing the power

Seite 19 - 120 V, 4.5 A power supply

Section 2. InstallationInspection, Cleaning, and Packaging24 Operating Manual for XPD Series Power SupplyInspection, Cleaning, and PackagingInitialIn

Seite 20 - Electrical Specifications

Section 2. InstallationReturning Power Supplies to the ManufacturerRelease A 25Returning Power Supplies to the ManufacturerReturnMaterialAuthorization

Seite 21 - Input Conditions

Section 2. InstallationReturning Power Supplies to the Manufacturer26 Operating Manual for XPD Series Power SupplyPackaging forShipping orStorageFoll

Seite 22 - Additional Characteristics

Section 2. InstallationLocation, Mounting, and VentilationRelease A 27Location, Mounting, and VentilationYou may use the 500 watt power supply in rack

Seite 23 - Mechanical Specifications

Operating Manual forXPD SeriesProgrammable DC Power Supply

Seite 24

Section 2. InstallationAC Input Power Connection28 Operating Manual for XPD Series Power SupplyAC Input Power ConnectionAC InputConnectorThe AC input

Seite 25 - Section 2. Installation

Section 2. InstallationFunctional TestsRelease A 29Functional TestsThese functional test procedures include power-on and front panel function checks a

Seite 26

Section 2. InstallationLoad Connection30 Operating Manual for XPD Series Power SupplyLoad ConnectionThis section provides recommendations for load wi

Seite 27

Section 2. InstallationLoad ConnectionRelease A 31Figure 2.2 Maximum Load Wire Length for 1 V Line DropNoise and Impedance Effects To minimize noise p

Seite 28

Section 2. InstallationLoad Connection32 Operating Manual for XPD Series Power SupplyInductiveLoadsTo prevent damage to the power supply from inducti

Seite 29

Section 2. InstallationRemote SensingRelease A 33Remote SensingRemote sensing permits you to shift the regulation point of the power supply from the o

Seite 30 - AC Input Power Connection

Section 2. InstallationRemote Sensing34 Operating Manual for XPD Series Power SupplyTo compensate for losses in power leads connected to the output,

Seite 31 - Functional Tests

Release A 35Section 3. Local OperationIntroductionOnce you have installed the power supply, it is ready to operate in local control mode (that is, ope

Seite 32 - Load Connection

Section 3. Local OperationStandard Operation36 Operating Manual for XPD Series Power SupplyFigure 3.1 Operating ModesConstantVoltage ModeOperationThe

Seite 33 - Release A 31

Section 3. Local OperationShipped Configuration (Local Control Mode)Release A 374. Disconnect the shorting lead from the output terminals. The power s

Seite 34

ii Operating Manual for XPD Series Power SupplyLimitedWarrantyWhat does this warranty cover and how long does it last?This Limited Warranty is provi

Seite 35 - Remote Sensing

Section 3. Local OperationUsing Over Voltage Protection (OVP)38 Operating Manual for XPD Series Power SupplyUsing Over Voltage Protection (OVP)The OV

Seite 36

Section 3. Local OperationUsing the Shutdown FunctionRelease A 39Using the Shutdown FunctionUse the shutdown function to disable or enable the supply’

Seite 37 - Section 3. Local Operation

Section 3. Local OperationUsing Multiple Supplies40 Operating Manual for XPD Series Power SupplyUsing Multiple SuppliesYou can operate power supplies

Seite 38 - Figure 3.1 Operating Modes

Section 3. Local OperationUsing Multiple SuppliesRelease A 41Configuring Multiple Supplies for Series Operation (Voltage Mode Only)Connect power suppl

Seite 39 - Release A 37

Section 3. Local OperationUsing Multiple Supplies42 Operating Manual for XPD Series Power SupplyConfiguring Multiple Supplies for Parallel OperationC

Seite 40

Section 3. Local OperationUsing Multiple SuppliesRelease A 43Configuring Multiple Supplies for Split Supply OperationSplit supply operating uses two p

Seite 41 - Master-Slave Tracking

Section 3. Local OperationUsing Multiple Supplies44 Operating Manual for XPD Series Power SupplyPositive-negative supply To obtain a positive-negativ

Seite 42 - Using Multiple Supplies

Section 3. Local OperationUser DiagnosticsRelease A 45User DiagnosticsIf your power supply is not performing as described in this manual, run through

Seite 43 - Figure 3.2 Series Operation

Section 3. Local OperationUser Diagnostics46 Operating Manual for XPD Series Power SupplyTable 3.2 User DiagnosticsSymptom Check Further Checks and C

Seite 44

Section 3. Local OperationUser DiagnosticsRelease A 47Output voltage fluctuating or regulation poor.Is unit at current limit? Increase current limit s

Seite 45 - Power Supply 1

Release A iiiDirect returns may be performed according to the Xantrex Return Material Authorization Policy described in your product manual. For some

Seite 46

Section 3. Local OperationUser Diagnostics48 Operating Manual for XPD Series Power Supply

Seite 47 - User Diagnostics

Release A 49Section 4. Remote OperationIntroductionThe switches and connector on the rear panel of the power supply allow you to program the supply wi

Seite 48 - Table 3.2 User Diagnostics

Section 4. Remote OperationReadback and Status Indicators50 Operating Manual for XPD Series Power SupplyRemoteProgrammingOptionsSee Table 4.1 for a s

Seite 49 - Release A 47

Section 4. Remote OperationStatus FlagsRelease A 51Status FlagsThe power supply has 5 status flags to indicate the operating state. The S/D LED on the

Seite 50

Section 4. Remote OperationStatus Flags52 Operating Manual for XPD Series Power Supply

Seite 52

Xantrex Technology Inc.8999 Nelson Way Burnaby, British Columbia Canada V5A 4B5604 422 8595 Tel604 421 3056 Fax800 667 8422 Toll Free North America

Seite 53 - Status Flags

iv Operating Manual for XPD Series Power SupplyDisclaimer ProductTHIS LIMITED WARRANTY IS THE SOLE AND EXCLUSIVE WARRANTY PROVIDED BY XANTREX IN CON

Seite 54

Release A vInformation WITHOUT LIMITING THE GENERALITY OF THE FOREGOING, UNLESS SPECIFICALLY AGREED TO BY IT IN WRITING, XANTREX a. MAKES NO WARRANTY

Seite 55

vi Operating Manual for XPD Series Power SupplyWarningsandCautionsWarnings and cautions are defined and formatted in this manual as shown below.Powe

Seite 56 - PRINTED IN CANADA

Release A viiAbout This ManualThis Operating Manual contains operating information for the XPD Series of high-performance, switching, laboratory power

Kommentare zu diesen Handbüchern

Keine Kommentare