ENET-XFR
ENET-XFR3
TM-XR9B-01XN.book Page i Monday, April 19, 2004 9:00 AM
Seitenansicht 0
1 2 3 4 5 6 ... 99 100

Inhaltsverzeichnis

Seite 1 - Power Supplies

Internal Ethernet and RS-232 Interface for XFR Series Programmable DC Power SuppliesOperating ManualENET-XFRENET-XFR3TM-XR9B-01XN.book Page i Monday

Seite 2

viiiTM-XR9B-01XN.book Page viii Monday, April 19, 2004 9:00 AM

Seite 3 - Ethernet/RS-232 Interface

Xantrex Technology Inc.1 800 670 0707 Tel toll free NA1 360 925 5097 Tel direct1 800 994 7828 Fax toll free NA1 360 925 5143 Fax directcustomerservice

Seite 4

TM-XR9B-01XN ixImportant Safety Instructions - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - vii1FeaturesDescription - - - - - - -

Seite 5 - About This Manual

Contentsx TM-XR9B-01XNBaud Rate Selection - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–18Flow Control Selection

Seite 6 - Organization

ContentsTM-XR9B-01XN xi4CalibrationIntroduction - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -4–1V

Seite 7 - Related Information

xiiTM-XR9B-01XN.book Page xii Monday, April 19, 2004 9:00 AM

Seite 8

TM-XR9B-01XN xiiiFigure 1-1 Sample configuration using Ethernet/RS-232 Interface(1200 Watt DC Power Supplies Shown) - - - - - - - - - - - - - - - - -

Seite 9 - Important Safety Instructions

xivTM-XR9B-01XN.book Page xiv Monday, April 19, 2004 9:00 AM

Seite 10

TM-XR9B-01XN xvTable 2-1 Remote Programming LEDs - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–4Table 2-2 Ethernet/RS-232 Interface Jum

Seite 11 - Contents

xviTM-XR9B-01XN.book Page xvi Monday, April 19, 2004 9:00 AM

Seite 12 - Operation

1FeaturesDescriptionThe Ethernet/RS-232 Interface is a microprocessor-controlled option card for all models of the XFR series of DC output power suppl

Seite 13 - TM-XR9B-01XN xi

TM-XR9B-01XN.book Page ii Monday, April 19, 2004 9:00 AM

Seite 14

Features1–2 TM-XR9B-01XNFeatures and FunctionsInterface Features• Programmable soft limits for voltage and current• Programmable over voltage protecti

Seite 15 - TM-XR9B-01XN xiii

Features and FunctionsTM-XR9B-01XN 1–3Ethernet Features• Auto-sensing 10/100Base-T network interface• Robust onboard TCP/IP stack supports:•TCP/UDP• U

Seite 16

1–4TM-XR9B-01XN.book Page 4 Monday, April 19, 2004 9:00 AM

Seite 17 - TM-XR9B-01XN xv

2Installation and ConfigurationIntroductionThe Ethernet/RS-232 Interface is usually installed at the factory. Your local distributor or service center

Seite 18

Installation and Configuration2–2 TM-XR9B-01XNAlso, depending on your specific configuration, you will need additional items.For Ethernet (via network

Seite 19 - Features

Initial InspectionTM-XR9B-01XN 2–3Initial InspectionOn first receiving your unit, perform a quick physical check. • Ensure each package contains a pow

Seite 20 - Features and Functions

Installation and Configuration2–4 TM-XR9B-01XNFront PanelFigure 2-1 shows the front panel of an XFR 1200 Watt supply with Ethernet/RS-232 Interface in

Seite 21 - Readback Functions

Initial InspectionTM-XR9B-01XN 2–5Ethernet/RS-232 Interface Subplate and PCBThe Ethernet/RS-232 Interface Subplate is visible from the rear panel of t

Seite 22

Installation and Configuration2–6 TM-XR9B-01XNFigure 2-3 shows the internal components on the Ethernet/RS-232 Interface PCB. Table 2-5 shows which jum

Seite 23 - Configuration

Initial InspectionTM-XR9B-01XN 2–7Table 2-2Ethernet/RS-232 Interface Jumper SelectionsJ2 Baud rate selection (default 9600)page 2–18 B1 (5-6) [closed]

Seite 24 - 2–2 TM-XR9B-01XN

XFR 1.2kW and 2.8kW Ethernet/RS-232 Interface OptionOperating ManualTM-XR9B-01XN.book Page i Monday, April 19, 2004 9:00 AM

Seite 25 - Initial Inspection

Installation and Configuration2–8 TM-XR9B-01XNChanging Internal JumpersSome of the settings on the Ethernet/RS-232 Interface card are user selectable

Seite 26 - Front Panel

Changing Internal JumpersTM-XR9B-01XN 2–9Once that is complete, turn the board over and, if necessary, remove the short ribbon cable connected to J64

Seite 27 - Figure 2-2

Installation and Configuration2–10 TM-XR9B-01XNBasic Setup Procedure - EthernetThis procedure can be used as a quick reference for those familiar with

Seite 28

Basic Setup Procedure - RS-232TM-XR9B-01XN 2–11Basic Setup Procedure - RS-232This procedure can be used as a quick reference for those familiar with t

Seite 29 - Table 2-2

Installation and Configuration2–12 TM-XR9B-01XNConfiguring for Ethernet or RS-232This interface card can be configured for Ethernet communication, or

Seite 30 - REMOVE THESE SCREWS

Ethernet CommunicationsTM-XR9B-01XN 2–13Ethernet CommunicationsEthernet ConnectionThere are two options for controlling your XFR power supply via Ethe

Seite 31 - Procedure for 2.8kW XFR

Installation and Configuration2–14 TM-XR9B-01XNLocating the Power Supply on Your Network1. Record the MAC address for your power supply. This will be

Seite 32

Ethernet CommunicationsTM-XR9B-01XN 2–15Configuring Ethernet BridgeThe Ethernet/RS-232 Interface card has an Ethernet Bridge that converts the etherne

Seite 33

Installation and Configuration2–16 TM-XR9B-01XNInstalling and Using RealPort®1BackgroundRealPort® software allows you to keep using your existing appl

Seite 34

RS-232 CommunicationsTM-XR9B-01XN 2–17RS-232 CommunicationsRS-232 ConnectionUse an approved RS-232 connector and null modem cable when connecting the

Seite 35 - Ethernet Communications

About XantrexXantrex Technology Inc. is a world-leading supplier of advanced power electronics and controls with products from 50 watt mobile units to

Seite 36 - 2–14 TM-XR9B-01XN

Installation and Configuration2–18 TM-XR9B-01XNBaud Rate SelectionSerial transmission sends and receives data in bit streams at fixed bit rates. Both

Seite 37 - Configuring Ethernet Bridge

RS-232 CommunicationsTM-XR9B-01XN 2–19Flow Control SelectionFlow control signals regulate data flow for proper communication. To enable or disable the

Seite 38 - Using RealPort®

Installation and Configuration2–20 TM-XR9B-01XNRemote/Local OperationRemote/Local Mode StartupThe power supply can be set to start-up in remote or loc

Seite 39 - RS-232 Communications

Remote/Local OperationTM-XR9B-01XN 2–21Remote Mode OperationWhile in remote mode, use the interface commands to control the output of the power supply

Seite 40 - Baud Rate Selection

Installation and Configuration2–22 TM-XR9B-01XNLocal Mode OperationIn local mode operation, you set the voltage and current output levels and the OVP

Seite 41 - Flow Control Selection

Power Supply SettingsTM-XR9B-01XN 2–23Local Lockout (LLO) CommandUse the Local Lockout command to disable the LOCAL button on the power supply front p

Seite 42 - Remote/Local Operation

Installation and Configuration2–24 TM-XR9B-01XNAdditional User Options and SettingsYou can customize remote operation settings for OVP (over voltage p

Seite 43 - Remote Mode Operation

Additional User Options and SettingsTM-XR9B-01XN 2–25TTL Shutdown PolarityYou can use the Shutdown function to disable or enable the supply's out

Seite 44 - Remote Enable (REN) Command

Installation and Configuration2–26 TM-XR9B-01XNUser SignalsUser Lines ConnectorAuxiliary User Lines connector, located on the Ethernet/RS-232 Interfac

Seite 45 - LLO Set Local Lockout

User SignalsTM-XR9B-01XN 2–27Figure 2-6User Lines Signal Connector Circuit Block DiagramTM-XR9B-01XN.book Page 27 Monday, April 19, 2004 9:00 AM

Seite 46 - OVP Selection

iiiAbout This ManualPurposeThis Operating Manual is for the XFR 1.2kW and 2.8kW Ethernet/RS-232 Interface Option; a microprocessor-controlled option c

Seite 47 - TTL Shutdown Polarity

Installation and Configuration2–28 TM-XR9B-01XNUser Lines Cable ConnectionUse a standard 8-position telephone jack and data cable to connect to the us

Seite 48 - User Signals

3OperationIntroductionThis section covers Ethernet/RS-232 Interface programming, including an extensive set of device-dependent commands, error codes,

Seite 49 - Figure 2-6

Operation3–2 TM-XR9B-01XNRS-232 OperationWhen the Ethernet/RS-232 Interface card is configured for RS-232 you can send and receive data between your p

Seite 50 - User Lines Cable Connection

Command SyntaxTM-XR9B-01XN 3–3Command Format and ParametersThe device-dependent language for the Ethernet/RS-232 Interface consists of commands and pa

Seite 51

Operation3–4 TM-XR9B-01XNFloating Point Number <float>Variables sent with command parameters are floating point numbers. Table 3-2 defines the s

Seite 52 - Command Syntax

Command SyntaxTM-XR9B-01XN 3–5Command StringsIf you send more than one command line, separate the commands with a semicolon. The semicolon may be prec

Seite 53 - Command Format and Parameters

Operation3–6 TM-XR9B-01XNCommand SummaryUse these commands to control the operation of the supply. They are listed here in order of function such as P

Seite 54

Command SummaryTM-XR9B-01XN 3–7Table 3-4Query CommandsAUXA? Asks for the state of the set value for the AUXA commandAUXB? Asks for the state of the se

Seite 55 - Command Terminators

Operation3–8 TM-XR9B-01XNTable 3-5Calibration CommandsCMODE Places the supply into calibration mode.IDATA Calculates the slope and intercept for curre

Seite 56 - Command Summary

Command ReferenceTM-XR9B-01XN 3–9Command ReferenceTable 3-7Command ReferenceASTS? Asks for the supply’s accumulated status register. The accumulated s

Seite 57 - Query Commands

About This Manualiv TM-XR9B-01XNOrganizationThis Manual is organized into 4 chapters and 2 appendixes.Chapter 1, “Features” Describes the interface an

Seite 58 - Status Commands

Operation3–10 TM-XR9B-01XNDLY <seconds> Sets a programmable time delay employed by the supply before reporting fault conditions. The power suppl

Seite 59 - Command Reference

Command ReferenceTM-XR9B-01XN 3–11FOLD? Asks for the supply’s present foldback setting.Response: FOLD <mode> where mode is: 0 (OFF) or1 (CV or

Seite 60 - Table 3-7

Operation3–12 TM-XR9B-01XNIMAX <current> Sets an upper soft limit on the supply’s programmed output current. If the soft limit is exceeded, or i

Seite 61

Command ReferenceTM-XR9B-01XN 3–13LLO Disables the front panel LOCAL switch. When LLO is in effect you can only return to local mode using the GTL com

Seite 62

Operation3–14 TM-XR9B-01XNREN <1/ON>, <0/OFF>Remote Enable. When set to REN 0, the power supply is in local mode. If a command is sent fro

Seite 63

Command ReferenceTM-XR9B-01XN 3–15UNMASK? Asks for the supply's fault conditions which are currently enabled (unmasked).Response: UNMASK <faul

Seite 64

Operation3–16 TM-XR9B-01XNVRHI The power supply outputs a voltage value to an external voltmeter connected as part of the calibration procedure and re

Seite 65

Accumulated Status, Status, and Fault RegistersTM-XR9B-01XN 3–17Accumulated Status, Status, and Fault RegistersThe Ethernet/RS-232 Interface card uses

Seite 66

Operation3–18 TM-XR9B-01XNNotes:1. All mnemonics can be masked or unmasked.2. The error (ERR) bit is reset in the accumulated status, status, and seri

Seite 67

Error CodesTM-XR9B-01XN 3–19Error CodesIf the ERR flag in the accumulated status or fault registers has been activated, an ERR? query will return an e

Seite 68 - Table 3-8

About This ManualTM-XR9B-01XN vConventions UsedThe following conventions are used in this guide.Related InformationYou can find more information about

Seite 69 - Error Codes

Operation3–20 TM-XR9B-01XNTroubleshootingDiagnostic LEDsThis section describes the diagnostic LEDs found on the Ethernet/RS-232 Interface.Computer Ope

Seite 70 - Troubleshooting

TroubleshootingTM-XR9B-01XN 3–21Ethernet Mode Troubleshooting TipsTable 3-10Ethernet Mode TipsCannot establish communication or cannot find XFR on net

Seite 71 - Ethernet Mode Tips

Operation3–22 TM-XR9B-01XNAble to connect to the device server (Ethernet Bridge), but unable to control or receive a response from the power supplyThe

Seite 72

TroubleshootingTM-XR9B-01XN 3–23RS-232 Mode Troubleshooting TipsRS-232 and/or Ethernet Mode Troubleshooting TipsTable 3-11RS-232 Mode TipsCannot estab

Seite 73 - Table 3-12

3–24TM-XR9B-01XN.book Page 24 Monday, April 19, 2004 9:00 AM

Seite 74

4CalibrationIntroductionYou can calibrate the interface in either Ethernet or RS-232 mode by adjusting the signal levels on the interface card so that

Seite 75 - Calibration

Calibration4–2 TM-XR9B-01XNYou can calibrate the Ethernet/RS-232 Interface for:• Voltage program• Voltage readback • Current program • Current readbac

Seite 76 - 4–2 TM-XR9B-01XN

Voltage Mode CalibrationTM-XR9B-01XN 4–3Voltage Mode CalibrationVoltage Calibration Setup1. Disconnect the load from the power supply which is to be c

Seite 77 - Voltage Mode Calibration

Calibration4–4 TM-XR9B-01XNVoltage Readback Calibration Procedure1. Set the power supply for calibration as in Figure 4-1.2. Activate calibration mode

Seite 78 - 4–4 TM-XR9B-01XN

Current Mode CalibrationTM-XR9B-01XN 4–5Current Mode CalibrationCurrent Calibration Setup1. Disconnect the load from the power supply to be calibrated

Seite 79 - Current Mode Calibration

viTM-XR9B-01XN.book Page vi Monday, April 19, 2004 9:00 AM

Seite 80 - 4–6 TM-XR9B-01XN

Calibration4–6 TM-XR9B-01XN7. Program the supply at various levels using the ISET command to confirm that the calibration was successful and that line

Seite 81 - TM-XR9B-01XN 4–7

Over Voltage Protection (OVP) CalibrationTM-XR9B-01XN 4–7Over Voltage Protection (OVP) CalibrationWe recommend that you perform OVP calibration every

Seite 82

4–8TM-XR9B-01XN.book Page 8 Monday, April 19, 2004 9:00 AM

Seite 83 - Specifications

ASpecificationsThe specifications in this section are warranted at 25°C ±5°C unless otherwise specified. All specifications are subject to change with

Seite 84 - Interface Installed

SpecificationsA–2 TM-XR9B-01XNSpecifications for XFR 1.2kW with Ethernet/RS-232 Interface Installed Table A-1XFR 1.2kW 7.5 V to 40 VProgram Resolution

Seite 85 - XFR 1.2kW 60 V to 600 V

Specifications for XFR 1.2kW with Ethernet/RS-232 Interface InstalledTM-XR9B-01XN A–3Table A-2XFR 1.2kW 60 V to 600 VProgram ResolutionVo lt a geCurre

Seite 86

SpecificationsA–4 TM-XR9B-01XNSpecifications for XFR 2.8kW with Ethernet/RS-232 Interface InstalledTable A-3XFR 2.8kW 7.5 V to 40 VProgram ResolutionV

Seite 87 - XFR 2.8kW 60 V to 600 V

Specifications for XFR 2.8kW with Ethernet/RS-232 Interface InstalledTM-XR9B-01XN A–5Table A-4XFR 2.8kW 60 V to 600 VProgram ResolutionVo lt a geCurre

Seite 88

A–6TM-XR9B-01XN.book Page 6 Monday, April 19, 2004 9:00 AM

Seite 89 - Administration

BAdvanced Ethernet AdministrationAppendix B details how to change your network password, view port statistics and interpret LED information.TM-XR9B-01

Seite 90 - Changing the Root Password

viiImportant Safety InstructionsWARNING: High Energy and High VoltageExercise caution when using and calibrating a power supply. High energy levels ca

Seite 91 - Introduction

Advanced Ethernet AdministrationB–2 TM-XR9B-01XNChanging the Root PasswordFor security reason you will want to change the root password immediately. T

Seite 92 - Viewing Network Statistics

Resetting the Configuration to DefaultsTM-XR9B-01XN B–3Resetting the Configuration to DefaultsIntroductionThis procedure will reset the configuration

Seite 93 - Interpreting LED Information

Advanced Ethernet AdministrationB–4 TM-XR9B-01XNCopying the Configuration to and from a ServerThis procedure shows you how to copy the configuration t

Seite 94

Interpreting LED InformationTM-XR9B-01XN B–5Interpreting LED InformationEthernet Bridge LEDs provide information on port activity, diagnostics, and Et

Seite 95 - Information

B–6TM-XR9B-01XN.book Page 6 Monday, April 19, 2004 9:00 AM

Seite 96 - Disclaimer

TM-XR9B-01XN WA–1Warranty and Product InformationWarrantyWhat does this warranty cover? This Limited Warranty is provided by Xantrex Technology, Inc.

Seite 97 - Exclusions

Warranty and Product InformationWA–2 TM-XR9B-01XNProof of purchase may be in any one of the following forms:• The dated purchase receipt from the orig

Seite 98 - Information About Your System

TM-XR9B-01XN WA–3ExclusionsIf this product is a consumer product, federal law does not allow an exclusion of implied warranties. To the extent you are

Seite 99

Warranty and Product InformationWA–4 TM-XR9B-01XNReturn Procedure1. Package the unit safely, preferably using the original box and packing materials.

Seite 100 - Printed in Canada

TM-XR9B-01XN.book Page 3 Monday, April 19, 2004 9:00 AM

Kommentare zu diesen Handbüchern

Keine Kommentare